Infrastructure

We design and implement the networks, servers and systems your company runs on, from cabling to cloud.

We start from an audit of the existing setup, size for the years ahead (not just for today) and implement with equipment from certified vendors, keeping the right balance between performance and cost.

What goes into an infrastructure rack Rack elevation, top to bottom: patch panel for the structured cabling, core switch, access switch, firewall, virtualisation server, storage for data and backup, and a UPS for continuous power. // one cabinet, every layer 2UPatch panelstructured cabling1UCore switchaggregation1UAccess switchuser ports1UFirewallperimeter and VPN3UServervirtualisation2UStoragedata and backup3UUPScontinuous power // Vertiv Romania relocation 60 kmCat6A cable1,300data and voice ports4technical rooms
We design the cabinet as a whole: cabling, network, security, compute, storage and power. Not six suppliers who do not talk to each other.

What we cover

  • Structured cabling. Network design, server room fit-out, Cat6/Cat6A/Cat7 and fibre optic cabling, with Fluke Networks testing and certification.
  • Network equipment. A validated network diagram and topology, traffic segmentation and prioritisation, delivery, installation, configuration and monitoring.
  • Server, storage and data center. We size for today’s needs and the estimated growth, commission the systems and provide maintenance, in and out of warranty.
  • Virtualisation. Virtualised servers, storage and network: resources used efficiently, lower costs, short recovery times after incidents.
  • Cloud computing. Virtual machines hosted in data centers, email servers, external backup for essential data.
  • Backup and Disaster Recovery. A backup plan sized on the company’s needs, local and off-site copies, constant verification and minimised recovery time.
  • Physical security. Access control, video surveillance, intercom, fire detection and burglary protection, designed as one with the network.
  • Uninterrupted power. UPS and generator solutions: design, procurement, commissioning.
How structured cabling rises through a building The ground-floor technical room feeds a vertical riser. On each floor, a patch panel runs from the riser to the data outlets. // from the server room to the socket on the desk Floor 3patch panelFloor 2patch panelFloor 1patch panelGroundServer room Risermain route between floorsFloor patch paneldistribution pointData outletstested and certified
Structured cabling is designed for the building, not for the room: riser, per-floor distribution, outlets tested and certified.

Talk to a specialist